Details
The Walk in fridge with insulated panels and refrigeration systems are manufactured as a system. The Walk in mortuary fridges are designed to accept all types of mortuary equipment. The panels are designed with cam lock latches for easy assembly and future expansion.
The refrigeration systems are pre-assembled with all controls factory tested prior to delivery.
Price on Application
Specifications
• Dimensions: 8'6"(260cm) L x 5'6"(167cm) W x 8'7"(260cm)H • (1) CPB050DC-A Refrigeration system • Approximate Total Shipping Weight (lbs) 1,968 Finishes: • 26 Gauge Corrosion Resistant Stucco Embossed Coated Steel- Interior wall, Exterior wall, Interior ceiling • 26 Gauge smooth galvanized-ceiling topside,floor bottom side • 14 Gauge Galvanized- Interior floor • (1) 48''(121cm) x78''(198cm) Walk-in Door left-hand swing • Includes door closer, cam lift hinges (one spring loaded), NL9800 deadbolt key/padlock handle with inside release, magnetic gasket, heater wire, digital thermometer, double sweep gasket &switch with pilot light. • (1)Double Wrap-Around Corner on Door Section (May Require a Different Handle and Inside Release) • (1) 48''(121cm) Exterior Ramp, Stainless steel With Non-Skid Strips Applied To Top (25-1/2''(63cm) Deep) • (1) Vapor proof Light Fixture (Shipped Loose For Field Installation). • (1) Small ceiling mount capsule-pak Refrigeration system opening (For Use With Non-Standard Capsule-Pak Locations) 37 Sq.Ft of 3/4 CDX Plywood Sub floor • (1) CPB050DC-A 4 Degrees Celsius Operation, Capsule-Pak Refrigeration System, Indoor Ceiling Mount High Temperature, ''Off Cycle''Timer,R-404A Refrigerant,115-1-60 Electrical Which Meets CEC Requirements. • System Overall Size Is 29"(73cm) Wide x 44.5"(111cm) Long and 14.5"(35cm) High.13.3 Total System AMPS,16.1 Minimum Circuit AMPS,20 Maximum Fuse Size.4.81 EER Rating (system capacity 3460BTU's/hour at 26.7 Degrees Celsius ambient temperature) • Calculated load for Cooler (4.0 Degrees Celsius) is 1901BTU's/hour calculated from 24 Degrees Celsius ambient temperature,21.1 Degrees Celsius floor temperature (insulated floor) 11 minutes of open door time per 24 hours for (1) 48"(121cm) x 78"(198cm) Walk in door opening into 24 Degrees Celsius ambient (normal usage). • (1) 100 watt lights operating 12 hours per day, no vent air, no people working in the room, no additional electrical load,and 175 pounds of cadavers entering the room at 24 Degrees Celsius to be cooled in 24 hours.Additional Information
Manufacturer | Unbranded |
---|